Log in | Register

Beware the siren’s song of novel endotracheal tube designs

Michael Klompas| Lorenzo Berra| Richard Branson
Editorial
Volume 43, Issue 11 / November , 2017

Pages 1708 - 1711

No abstract available.

References

  1. Metersky ML, Wang Y, Klompas M, Eckenrode S, Bakullari A, Eldridge N (2016) Trend in ventilator-associated pneumonia rates between 2005 and 2013. JAMA 316:2427–2429
    • View reference on publisher's website
    • View reference on PubMed
  2. Branson RD, Hess DR (2015) Lost in translation: failure of tracheal tube modifications to impact ventilator-associated pneumonia. Am J Respir Crit Care Med 191:606–608
    • View reference on publisher's website
    • View reference on PubMed
  3. Kollef MH, Afessa B, Anzueto A, Veremakis C, Kerr KM, Margolis BD, Craven DE, Roberts PR, Arroliga AC, Hubmayr RD, Restrepo MI, Auger WR, Schinner R (2008) Silver-coated endotracheal tubes and incidence of ventilator-associated pneumonia: the NASCENT randomized trial. JAMA 300:805–813
    • View reference on publisher's website
    • View reference on PubMed
  4. Berra L, De Marchi L, Yu ZX, Laquerriere P, Baccarelli A, Kolobow T (2004) Endotracheal tubes coated with antiseptics decrease bacterial colonization of the ventilator circuits, lungs, and endotracheal tube. Anesthesiology 100:1446–1456
    • View reference on publisher's website
    • View reference on PubMed
  5. Caroff DA, Li L, Muscedere J, Klompas M (2016) Subglottic secretion drainage and objective outcomes: a systematic review and meta-analysis. Crit Care Med 44:830–840
    • View reference on PubMed
  6. Valencia M, Ferrer M, Farre R, Navajas D, Badia JR, Nicolas JM, Torres A (2007) Automatic control of tracheal tube cuff pressure in ventilated patients in semirecumbent position: a randomized trial. Crit Care Med 35:1543–1549
    • View reference on publisher's website
    • View reference on PubMed
  7. Nseir S, Zerimech F, Fournier C, Lubret R, Ramon P, Durocher A, Balduyck M (2011) Continuous control of tracheal cuff pressure and microaspiration of gastric contents in critically ill patients. Am J Respir Crit Care Med 184:1041–1047
    • View reference on publisher's website
    • View reference on PubMed
  8. Zanella A, Scaravilli V, Isgro S, Milan M, Cressoni M, Patroniti N, Fumagalli R, Pesenti A (2011) Fluid leakage across tracheal tube cuff, effect of different cuff material, shape, and positive expiratory pressure: a bench-top study. Intensive Care Med 37:343–347
  9. Philippart F, Gaudry S, Quinquis L, Lau N, Ouanes I, Touati S, Nguyen JC, Branger C, Faibis F, Mastouri M, Forceville X, Abroug F, Ricard JD, Grabar S, Misset B, Group TO-CS (2015) Randomized intubation with polyurethane or conical cuffs to prevent pneumonia in ventilated patients. Am J Respir Crit Care Med 191:637–645
    • View reference on publisher's website
    • View reference on PubMed
  10. Jaillette E, Girault C, Brunin G, Zerimech F, Behal H, Chiche A, Broucqsault-Dedrie C, Fayolle C, Minacori F, Alves I, Barrailler S, Labreuche J, Robriquet L, Tamion F, Delaporte E, Thellier D, Delcourte C, Duhamel A, Nseir S (2017) Impact of tapered-cuff tracheal tube on micoaspiration of gastric contents in intubated critically ill patients: a multicenter cluster randomized cross-over controlled trial. Intensive Care Med. doi:10.1007/s00134-017-4736-x
    • View reference on PubMed
  11. Dewavrin F, Zerimech F, Boyer A, Maboudou P, Balduyck M, Duhamel A, Nseir S (2014) Accuracy of alpha amylase in diagnosing microaspiration in intubated critically-ill patients. PLoS One 9:e90851
    • View reference on publisher's website
    • View reference on PubMed
  12. Chenelle CT, Itagaki T, Fisher DF, Berra L, Kacmarek RM (2017) Performance of the PneuX System: a bench study comparison with 4 other endotracheal tube cuffs. Respir Care 62:102–112
    • View reference on publisher's website
    • View reference on PubMed
  13. Blunt MC, Young PJ, Patil A, Haddock A (2001) Gel lubrication of the tracheal tube cuff reduces pulmonary aspiration. Anesthesiology 95:377–381
    • View reference on publisher's website
    • View reference on PubMed
  14. Kolobow T, Cressoni M, Epp M, Corti I, Cadringher P, Zanella A (2011) Comparison of a novel lycra endotracheal tube cuff to standard polyvinyl chloride cuff and polyurethane cuff for fluid leak prevention. Respir Care. 56(8):1095–1099
    • View reference on publisher's website
    • View reference on PubMed
  15. Zanella A, Cressoni M, Epp M, Stylianou M, Kolobow T (2008) A double-layer tracheal tube cuff designed to prevent leakage: a bench-top study. Intensive Care Med 34:1145–1149
  16. Reali-Forster C, Kolobow T, Giacomini M, Hayashi T, Horiba K, Ferrans VJ (1996) New ultrathin-walled endotracheal tube with a novel laryngeal seal design. Long-term evaluation in sheep. Anesthesiology 84:162–172 (discussion 127A)
    • View reference on PubMed
  17. Ely EW (2017) The ABCDEF Bundle: science and philosophy of how ICU liberation serves patients and families. Crit Care Med 45:321–330
    • View reference on publisher's website
    • View reference on PubMed

Sign In

Connect with ICM

Top 5 Articles Editors Picks Supplement