Log in | Register

Effects of fluid administration on arterial load in septic shock patients

Manuel Ignacio Monge García| Pedro Guijo González| Manuel Gracia Romero| Anselmo Gil Cano| Chris Oscier| Andrew Rhodes| Robert Michael Grounds| Maurizio Cecconi
Original
Volume 41, Issue 7 / July , 2015

Pages 1247 - 1255

Abstract

Purpose

To determine the effects of fluid administration on arterial load in critically ill patients with septic shock.

Methods

Analysis of septic shock patients monitored with an oesophageal Doppler and equipped with an indwelling arterial catheter in whom a fluid challenge was performed because of the presence of systemic hypoperfusion. Measures of arterial load [systemic vascular resistance, SVR = mean arterial pressure (MAP)/cardiac output (CO); net arterial compliance, C = stroke volume (SV)/arterial pulse pressure; and effective arterial elastance, Ea = 90 % of systolic arterial pressure/SV] were studied both before and after volume expansion (VE).

Results

Eighty-one patients were analysed, 54 (67 %) increased their CO by at least 10 % after VE (preload responders). In the whole population, 29 patients (36 %) increased MAP by at least 10 % from preinfusion level (pressure responders). In the preload responder group, only 24 patients (44 %) were pressure responders. Fluid administration was associated with a significant decrease in Ea [from 1.68 (1.11–2.11) to 1.57 (1.08–1.99) mmHg/mL; P = 0.0001] and SVR [from 1035 (645–1483) to 928 (654–1452) dyn s cm−5; P < 0.01]. Specifically, in preload responders in whom arterial pressure did not change, VE caused a reduction in Ea from 1.74 (1.22–2.24) to 1.55 (1.24–1.86) mmHg/mL (P < 0.0001), affecting both resistive [SVR: from 1082 (697–1475) to 914 (624–1475) dyn s cm−5; P < 0.0001] and pulsatile [C: from 1.11 (0.84–1.49) to 1.18 (0.99–1.44) mL/mmHg; P < 0.05] components. There was no relationship between preinfusion arterial load parameters and VE-induced increase in arterial pressure.

Conclusion

Fluid administration significantly reduced arterial load in critically patients with septic shock and acute circulatory failure, even when increasing cardiac output. This explains why some septic patients increase their cardiac output after fluid administration without improving blood pressure.

Keywords

References

  1. Starling MR (1993) Left ventricular-arterial coupling relations in the normal human heart. Am Heart J 125:1659–1666
    • View reference on PubMed
    • View reference on publisher's website
  2. Sunagawa K, Maughan WL, Burkhoff D, Sagawa K (1983) Left ventricular interaction with arterial load studied in isolated canine ventricle. Am J Physiol 245:H773–H780
    • View reference on PubMed
  3. Chantler PD, Lakatta EG (2012) Arterial-ventricular coupling with aging and disease. Front Physiol 3:90
    • View reference on PubMed
    • View reference on publisher's website
  4. Guarracino F, Baldassarri R, Pinsky MR (2013) Ventriculo-arterial decoupling in acutely altered hemodynamic states. Crit Care 17:213
    • View reference on PubMed
    • View reference on publisher's website
  5. Asanoi H, Kameyama T, Ishizaka S, Nozawa T, Inoue H (1996) Energetically optimal left ventricular pressure for the failing human heart. Circulation 93:67–73
    • View reference on PubMed
    • View reference on publisher's website
  6. Chantler PD, Lakatta EG, Najjar SS (2008) Arterial-ventricular coupling: mechanistic insights into cardiovascular performance at rest and during exercise. J Appl Physiol 105:1342–1351
    • View reference on PubMed
    • View reference on publisher's website
  7. Guarracino F, Ferro B, Morelli A, Bertini P, Baldassarri R, Pinsky MR (2014) Ventriculoarterial decoupling in human septic shock. Crit Care 18:R80
    • View reference on PubMed
    • View reference on publisher's website
  8. Vieillard-Baron A (2011) Septic cardiomyopathy. Ann Intensive Care 1:6
    • View reference on PubMed
    • View reference on publisher's website
  9. Ochagavia A, Baigorri F, Mesquida J, Ayuela JM, Ferrandiz A, Garcia X, Monge MI, Mateu L, Sabatier C, Clau-Terre F, Vicho R, Zapata L, Maynar J, Gil A, Grupo de Trabajo de Cuidados Intensivos Cardiologicos y RCPdlS (2014) Hemodynamic monitoring in the critically patient. Recomendations of the Cardiological Intensive Care and CPR Working Group of the Spanish Society of Intensive Care and Coronary Units. Med Intensiva 38:154–169
    • View reference on PubMed
    • View reference on publisher's website
  10. Cecconi M, De Backer D, Antonelli M, Beale R, Bakker J, Hofer C, Jaeschke R, Mebazaa A, Pinsky MR, Teboul JL, Vincent JL, Rhodes A (2014) Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine. Intensive Care Med 40:1795–1815
  11. Dellinger RP, Levy MM, Rhodes A, Annane D, Gerlach H, Opal SM, Sevransky JE, Sprung CL, Douglas IS, Jaeschke R, Osborn TM, Nunnally ME, Townsend SR, Reinhart K, Kleinpell RM, Angus DC, Deutschman CS, Machado FR, Rubenfeld GD, Webb S, Beale RJ, Vincent JL, Moreno R, Surviving Sepsis Campaign Guidelines Committee including The Pediatric S (2013) Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock, 2012. Intensive Care Med 39:165–228
  12. Westerhof N, Lankhaar JW, Westerhof BE (2009) The arterial Windkessel. Med Biol Eng Comput 47:131–141
    • View reference on PubMed
    • View reference on publisher's website
  13. Segers P, Stergiopulos N, Westerhof N (2002) Relation of effective arterial elastance to arterial system properties. Am J Physiol Heart Circ Physiol 282:H1041–H1046
    • View reference on PubMed
    • View reference on publisher's website
  14. Kelly RP, Ting CT, Yang TM, Liu CP, Maughan WL, Chang MS, Kass DA (1992) Effective arterial elastance as index of arterial vascular load in humans. Circulation 86:513–521
    • View reference on PubMed
    • View reference on publisher's website
  15. Sunagawa K, Maughan WL, Sagawa K (1985) Optimal arterial resistance for the maximal stroke work studied in isolated canine left ventricle. Circ Res 56:586–595
    • View reference on PubMed
    • View reference on publisher's website
  16. Chemla D, Antony I, Lecarpentier Y, Nitenberg A (2003) Contribution of systemic vascular resistance and total arterial compliance to effective arterial elastance in humans. Am J Physiol Heart Circ Physiol 285:H614–H620
    • View reference on PubMed
    • View reference on publisher's website
  17. Pauca AL, Wallenhaupt SL, Kon ND, Tucker WY (1992) Does radial artery pressure accurately reflect aortic pressure? Chest 102:1193–1198
    • View reference on PubMed
    • View reference on publisher's website
  18. Hatib F, Jansen JR, Pinsky MR (2011) Peripheral vascular decoupling in porcine endotoxic shock. J Appl Physiol 111:853–860
    • View reference on PubMed
    • View reference on publisher's website
  19. Monge Garcia MI, Romero MG, Cano AG, Rhodes A, Grounds RM, Cecconi M (2013) Impact of arterial load on the agreement between pulse pressure analysis and esophageal Doppler. Crit Care 17:R113
    • View reference on PubMed
    • View reference on publisher's website
  20. Asanoi H, Sasayama S, Kameyama T (1989) Ventriculoarterial coupling in normal and failing heart in humans. Circ Res 65:483–493
    • View reference on PubMed
    • View reference on publisher's website
  21. Nichols WW, O’Rourke M (2005) Vascular impedance. In: Nichols WW, O’Rourke M (eds) McDonald’s blood flow in arteries: theoretical, experimental and clinical principles. Oxford University Press, London, pp 233–267
  22. Cholley BP, Lang RM, Berger DS, Korcarz C, Payen D, Shroff SG (1995) Alterations in systemic arterial mechanical properties during septic shock: role of fluid resuscitation. Am J Physiol 269:H375–H384
    • View reference on PubMed
  23. Ricard-Hibon A, Losser MR, Kong R, Beloucif S, Teisseire B, Payen D (1998) Systemic pressure-flow reactivity to norepinephrine in rabbits: impact of endotoxin and fluid loading. Intensive Care Med 24:959–966
  24. Dellinger RP (2006) Fluid therapy of tissue hypoperfusion. In: Pinsky MR, Payen D (eds) Functional hemodynamic monitoring. Springer, Berlin, pp 285–298
  25. Nichols WW, O’Rourke M (2005) McDonald’s blood flow in arteries: theoretical, experimental and clinical principles. Oxford University Press, London
  26. Pohl U, De Wit C, Gloe T (2000) Large arterioles in the control of blood flow: role of endothelium-dependent dilation. Acta Physiol Scand 168:505–510
    • View reference on PubMed
    • View reference on publisher's website
  27. Losser MR, Forget AP, Payen D (2006) Nitric oxide involvement in the hemodynamic response to fluid resuscitation in endotoxic shock in rats. Crit Care Med 34:2426–2431
    • View reference on PubMed
    • View reference on publisher's website
  28. Milnor WR (1989) Hemodynamics. Williams & Wilkins, Baltimore
  29. Pinsky MR (2003) Hemodynamic monitoring in the intensive care unit. Clin Chest Med 24:549–560
    • View reference on PubMed
    • View reference on publisher's website
  30. Urzua J, Meneses G, Fajardo C, Lema G, Canessa R, Sacco CM, Medel J, Vergara ME, Irarrazaval M, Moran S (1997) Arterial pressure-flow relationship in patients undergoing cardiopulmonary bypass. Anesth Analg 84:958–963
    • View reference on PubMed
  31. Pierrakos C, Velissaris D, Scolletta S, Heenen S, De Backer D, Vincent JL (2012) Can changes in arterial pressure be used to detect changes in cardiac index during fluid challenge in patients with septic shock? Intensive Care Med 38:422–428
  32. Monnet X, Letierce A, Hamzaoui O, Chemla D, Anguel N, Osman D, Richard C, Teboul JL (2011) Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine. Crit Care Med 39:1394–1399
    • View reference on PubMed
    • View reference on publisher's website
  33. Lakhal K, Ehrmann S, Perrotin D, Wolff M, Boulain T (2013) Fluid challenge: tracking changes in cardiac output with blood pressure monitoring (invasive or non-invasive). Intensive Care Med 39:1953–1962
  34. Monge Garcia M, Gracia Romero M, Gil Cano A, Aya HD, Rhodes A, Grounds R, Cecconi M (2014) Dynamic arterial elastance as a predictor of arterial pressure response to fluid administration: a validation study. Crit Care 18:626
    • View reference on publisher's website
  35. Monge Garcia MI, Gil Cano A, Gracia Romero M (2011) Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients. Crit Care 15:R15
    • View reference on PubMed
    • View reference on publisher's website
  36. Cecconi M, Monge Garcia MI, Gracia Romero M, Mellinghoff J, Caliandro F, Grounds RM, Rhodes A (2014) The use of pulse pressure variation and stroke volume variation in spontaneously breathing patients to assess dynamic arterial elastance and to predict arterial pressure response to fluid administration. Anesth Analg 120:76–84
    • View reference on publisher's website
  37. Colquhoun DA, Roche AM (2014) Oesophageal Doppler cardiac output monitoring: a longstanding tool with evolving indications and applications. Best Pract Res Clin Anaesthesiol 28:353–362
    • View reference on PubMed
    • View reference on publisher's website
  38. Buda AJ, Pinsky MR, Ingels NB Jr, Daughters GT 2nd, Stinson EB, Alderman EL (1979) Effect of intrathoracic pressure on left ventricular performance. N Engl J Med 301:453–459
    • View reference on PubMed
    • View reference on publisher's website