Optimal fluid management is one of the main challenges in the care of the critically ill. However, the physiological parameters that are commonly monitored and used to guide fluid management are often inadequate and even misleading. From 1987 to 1989 we published four experimental studies which described a method for predicting the response of the cardiac output to fluid administration during mechanical ventilation. The method is based on the analysis of the variations in the arterial pressure in response to a mechanical breath, which serves as a repetitive hemodynamic challenge. Our studies showed that the systolic pressure variation and its components are able to reflect even small changes in the circulating blood volume. Moreover, these dynamic parameters provide information about the slope of the left ventricular function curve, and therefore predict the response to fluid administration better than static preload parameters.

Many new dynamic parameters have been introduced since then, including the pulse pressure (PPV) and stroke volume (SVV) variations, and various echocardiographic and other parameters. Though seemingly different, all these parameters are based on measuring the response to a predefined preload-modifying maneuver. The clinical usefulness of these ‘dynamic’ parameters is limited by many confounding factors, the recognition of which is absolutely necessary for their proper use.

With more than 20 years of hindsight we believe that our early studies helped pave the way for the recognition that fluid administration should ideally be preceded by the assessment of “fluid responsiveness”. The introduction of dynamic parameters into clinical practice can therefore be viewed as a significant step towards a more rational approach to fluid management.

Keywords

References

  1. Perel A, Pizov R, Cotev S (1987) Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology 67:498–502
    • View reference on PubMed
    • View reference on publisher's website
  2. Pizov R, Ya’ari Y, Perel A (1988) Systolic pressure variation is greater during hemorrhage than during sodium nitroprusside-induced hypotension in ventilated dogs. Anesth Analg 67:170–174
    • View reference on PubMed
    • View reference on publisher's website
  3. Pizov R, Segal E, Kaplan L, Floman Y, Perel A (1990) The use of systolic pressure variation in hemodynamic monitoring during deliberate hypotension in spine surgery. J Clin Anesth 2:96–100
    • View reference on PubMed
    • View reference on publisher's website
  4. Pizov R, Ya’ari Y, Perel A (1989) The arterial pressure waveform during acute ventricular failure and synchronized external chest compression. Anesth Analg 68:150–156
    • View reference on PubMed
    • View reference on publisher's website
  5. Szold A, Pizov R, Segal E, Perel A (1989) The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs. Intensive Care Med 15:368–371
  6. Perel A (1998) Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients. Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 89:1309–1310
    • View reference on PubMed
    • View reference on publisher's website
  7. Morgan BC, Martin WE, Hornbein TF, Crawford EW, Guntheroth WG (1966) Hemodynamic effects of intermittent positive pressure respiration. Anesthesiology 27:584–590
    • View reference on PubMed
    • View reference on publisher's website
  8. Massumi RA, Mason DT, Vera Z, Zelis R, Otero J, Amsterdam EA (1973) Reversed pulsus paradoxus. N Eng J Med 289:1272–1275
    • View reference on publisher's website
  9. Jardin F, Farcot JC, Gueret P, Prost JF, Ozier Y, Bourdarias JP (1983) Cyclic changes in arterial pulse during respiratory support. Circulation 68:266–274
    • View reference on PubMed
    • View reference on publisher's website
  10. Robotham JL, Cherry D, Mitzner W, Rabson JL, Lixfeld W, Bromberger-Barnea B (1983) A re-evaluation of the hemodynamic consequences of intermittent positive pressure ventilation. Crit Care Med 11:783–793
    • View reference on PubMed
    • View reference on publisher's website
  11. Brower R, Wise RA, Hassapoyannes C, Bromberger-Barnea B, Permutt S (1985) Effect of lung inflation on lung blood volume and pulmonary venous flow. J Appl Physiol 58:954–963
    • View reference on PubMed
    • View reference on publisher's website
  12. Pinsky MR, Matuschak GM, Klain M (1985) Determinants of cardiac augmentation by elevations in intrathoracic pressure. J Appl Physiol 58:1189–1198
    • View reference on PubMed
  13. Coyle JP, Teplick RS, Long MC (1983) Respiratory variations in systemic arterial pressure as an indicator of volume status. Anesthesiology 59:A53
  14. Rick JJ, Burke SS (1978) Respirator paradox. South Med J 71(1376–1378):1382
  15. Fukamachi K, Irie H, Massiello A, Chen JF, Crouch R, Utoh J, Harasaki H, Golding LA, Kiraly RJ (1992) Effects of mechanical ventilation and spontaneous respiration on hemodynamics in calves with total artificial hearts. ASAIO J 38:M493–M496
    • View reference on PubMed
    • View reference on publisher's website
  16. Vieillard-Baron A, Chergui K, Augarde R, Prin S, Page B, Beauchet A, Jardin F (2003) Cyclic changes in arterial pulse during respiratory support revisited by Doppler echocardiography. Am J Respir Crit Care Med 168:671–676
    • View reference on PubMed
    • View reference on publisher's website
  17. Mesquida J, Kim HK, Pinsky MR (2011) Effect of tidal volume, intrathoracic pressure, and cardiac contractility on variations in pulse pressure, stroke volume, and intrathoracic blood volume. Intensive Care Med 37:1672–1679
  18. Pizov R, Eden A, Bystritski D, Kalina E, Tamir A, Gelman S (2012) Hypotension during gradual blood loss: waveform variables response and absence of tachycardia. Br J Anaesth 109:911–918
    • View reference on PubMed
    • View reference on publisher's website
  19. Perner A, De Backer D (2014) Understanding hypovolaemia. Intensive Care Med 40(4):613–615
  20. Le Manach Y, Hofer CK, Lehot JJ, Vallet B, Goarin JP, Tavernier B, Cannesson M (2012) Can changes in arterial pressure be used to detect changes in cardiac output during volume expansion in the perioperative period? Anesthesiology 117:1165–1174
    • View reference on PubMed
    • View reference on publisher's website
  21. Michard F, Teboul JL (2000) Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation. Crit Care 4:282–289
    • View reference on PubMed
    • View reference on publisher's website
  22. Perel A (2005) The physiological basis of arterial pressure variation during positive-pressure ventilation. Reanimation 14:162–171
    • View reference on publisher's website
  23. Michard F (2005) Changes in arterial pressure during mechanical ventilation. Anesthesiology 103:419–428
    • View reference on PubMed
    • View reference on publisher's website
  24. Pinsky MR (1997) The hemodynamic consequences of mechanical ventilation: an evolving story. Intensive Care Med 23:493–503
  25. Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:2000–2008
    • View reference on PubMed
    • View reference on publisher's website
  26. Bendjelid K, Romand JA (2003) Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care. Intensive Care Med 29:352–360
  27. Magder S (2004) Clinical usefulness of respiratory variations in arterial pressure. Am J Respir Crit Care Med 169:151–155
    • View reference on PubMed
    • View reference on publisher's website
  28. Marik PE, Cavallazzi R, Vasu T, Hirani A (2009) Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 37:2642–2647
    • View reference on PubMed
    • View reference on publisher's website
  29. Cannesson M, Aboy M, Hofer CK, Rehman M (2010) Pulse pressure variation: where are we today? J Clin Monit Comput 25:45–56
    • View reference on publisher's website
  30. Perel A, Habicher M, Sander M (2013) Bench-to-bedside review: functional hemodynamics during surgery—should it be used for all high-risk cases? Crit Care 17:203
    • View reference on PubMed
    • View reference on publisher's website
  31. Marik PE, Lemson J (2014) Fluid responsiveness: an evolution of our understanding. Br J Anaesth 112:617–620
    • View reference on PubMed
    • View reference on publisher's website
  32. Coriat P, Vrillon M, Perel A, Baron JF, Le Bret F, Saada M, Viars P (1994) A comparison of systolic blood pressure variations and echocardiographic estimates of end-diastolic left ventricular size in patients after aortic surgery. Anesth Analg 78:46–53
    • View reference on PubMed
    • View reference on publisher's website
  33. Tavernier B, Makhotine O, Lebuffe G, Dupont J, Scherpereel P (1998) Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 89:1313–1321
    • View reference on PubMed
    • View reference on publisher's website
  34. Michard F, Chemla D, Richard C, Wysocki M, Pinsky MR, Lecarpentier Y, Teboul JL (1999) Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit Care Med 159:935–939
    • View reference on PubMed
    • View reference on publisher's website
  35. Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162:134–138
    • View reference on PubMed
    • View reference on publisher's website
  36. Pizov R, Cohen M, Weiss Y, Segal E, Cotev S, Perel A (1996) Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform. Crit Care Med 24:1381–1387
    • View reference on PubMed
    • View reference on publisher's website
  37. Preisman S, Kogan S, Berkenstadt H, Perel A (2005) Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the respiratory systolic variation test and static preload indicators. Br J Anaesth 95:746–755
    • View reference on PubMed
    • View reference on publisher's website
  38. Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A (2001) Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 92:984–989
    • View reference on PubMed
    • View reference on publisher's website
  39. Reuter DA, Felbinger TW, Kilger E, Schmidt C, Lamm P, Goetz AE (2002) Optimizing fluid therapy in mechanically ventilated patients after cardiac surgery by on-line monitoring of left ventricular stroke volume variations. Comparison with aortic systolic pressure variations. Br J Anaesth 88:124–126
    • View reference on PubMed
    • View reference on publisher's website
  40. Reuter DA, Felbinger TW, Schmidt C, Kilger E, Goedje O, Lamm P, Goetz AE (2002) Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 28:392–398
  41. Reuter DA, Bayerlein J, Goepfert MS, Weis FC, Kilger E, Lamm P, Goetz AE (2003) Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med 29:476–480
    • View reference on PubMed
  42. Reuter DA, Kirchner A, Felbinger TW, Weis FC, Kilger E, Lamm P, Goetz AE (2003) Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med 31:1399–1404
    • View reference on PubMed
    • View reference on publisher's website
  43. Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL (2001) Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 119:867–873
    • View reference on PubMed
    • View reference on publisher's website
  44. Beaussier M, Coriat P, Perel A, Lebret F, Kalfon P, Chemla D, Lienhart A, Viars P (1995) Determinants of systolic pressure variation in patients ventilated after vascular surgery. J Cardiothorac Vasc Anesth 9:547–551
    • View reference on PubMed
    • View reference on publisher's website
  45. Slama M, Masson H, Teboul JL, Arnout ML, Susic D, Frohlich E, Andrejak M (2002) Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness. Am J Physiol Heart Circ Physiol 283:H1729–H1733
    • View reference on PubMed
  46. Vieillard-Baron A, Augarde R, Prin S, Page B, Beauchet A, Jardin F (2001) Influence of superior vena caval zone condition on cyclic changes in right ventricular outflow during respiratory support. Anesthesiology 95:1083–1088
    • View reference on PubMed
    • View reference on publisher's website
  47. Vieillard-Baron A, Chergui K, Rabiller A, Peyrouset O, Page B, Beauchet A, Jardin F (2004) Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med 30:1734–1739
    • View reference on PubMed
  48. Feissel M, Michard F, Faller JP, Teboul JL (2004) The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med 30:1834–1837
  49. Barbier C, Loubieres Y, Schmit C, Hayon J, Ricome JL, Jardin F, Vieillard-Baron A (2004) Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 30:1740–1746
    • View reference on PubMed
  50. Bendjelid K, Suter PM, Romand J (2004) The respiratory change in preejection period: a new method to predict fluid responsiveness. J Appl Physiol 96:337–342
    • View reference on PubMed
    • View reference on publisher's website
  51. Shamir M, Eidelman LA, Floman Y, Kaplan L, Pizov R (1999) Pulse oximetry plethysmographic waveform during changes in blood volume. Brit J Anaesth 82:178–181
    • View reference on PubMed
    • View reference on publisher's website
  52. Perel A (2003) The value of functional hemodynamic parameters in hemodynamic monitoring of ventilated patients. Anaesthesist 52:1003–1004
    • View reference on PubMed
    • View reference on publisher's website
  53. Dalibon N, Schlumberger S, Saada M, Fischler M, Riou B (1999) Haemodynamic assessment of hypovolemia under general anaesthesia in pigs submitted to graded haemorrhage and retransfusion. Br J Anaesth 82:97–103
    • View reference on PubMed
    • View reference on publisher's website
  54. Bennett-Guerrero E, Kahn RA, Moskowitz DM, Falcucci O, Bodian CA (2002) Comparison of arterial systolic pressure variation with other clinical parameters to predict the response to fluid challenges during cardiac surgery. Mt Sinai J Med 69:96–100
    • View reference on PubMed
  55. Pinsky MR (2002) Functional hemodynamic monitoring. Intensive Care Med 28:386–388
  56. Denault AY, Gasior TA, Gorcsan J, Mandarino WA, Deneault LG, Pinsky MR (1999) Determinants of aortic pressure variation during positive-pressure ventilation in man. Chest 116:176–186
    • View reference on PubMed
    • View reference on publisher's website
  57. Berkenstadt H, Friedman Z, Preisman S, Keidan I, Livingstone D, Perel A (2005) Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs. Br J Anaesth 94:721–726
    • View reference on PubMed
    • View reference on publisher's website
  58. Rinehart J, Islam T, Boud R, Nguyen A, Alexander B, Canales C, Cannesson M (2012) Visual estimation of pulse pressure variation is not reliable: a randomized simulation study. J Clin Monit Comput 26:191–196
    • View reference on PubMed
    • View reference on publisher's website
  59. Thiele RH, Colquhoun DA, Blum FE, Durieux ME (2012) The ability of anesthesia providers to visually estimate systolic pressure variability using the “eyeball” technique. Anesth Analg 115:176–181
    • View reference on PubMed
    • View reference on publisher's website
  60. Maguire S, Rinehart J, Vakharia S, Cannesson M (2011) Technical communication: respiratory variation in pulse pressure and plethysmographic waveforms: intraoperative applicability in a North American academic center. Anesth Analg 112:94–96
    • View reference on PubMed
    • View reference on publisher's website
  61. Mahjoub Y, Lejeune V, Muller L, Perbet S, Zieleskiewicz L, Bart F, Veber B, Paugam-Burtz C, Jaber S, Ayham A, Zogheib E, Lasocki S, Vieillard-Baron A, Quintard H, Joannes-Boyau O, Plantefeve G, Montravers P, Duperret S, Lakhdari M, Ammenouche N, Lorne E, Slama M, Dupont H (2014) Evaluation of pulse pressure variation validity criteria in critically ill patients: a prospective observational multicentre point-prevalence study. Br J Anaesth 112:681–685
    • View reference on PubMed
    • View reference on publisher's website
  62. Rooke GA, Schwid HA, Shapira Y (1995) The effect of graded hemorrhage and intravascular volume replacement on systolic pressure variation in humans during mechanical and spontaneous ventilation. Anesth Analg 80:925–932
    • View reference on PubMed
  63. Heenen S, De Backer D, Vincent JL (2006) How can the response to volume expansion in patients with spontaneous respiratory movements be predicted? Crit Care 10:R102
    • View reference on PubMed
    • View reference on publisher's website
  64. De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL (2005) Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 31:517–523
  65. Lansdorp B, Lemson J, van Putten MJ, de Keijzer A, van der Hoeven JG, Pickkers P (2012) Dynamic indices do not predict volume responsiveness in routine clinical practice. Br J Anaesth 108:395–401
    • View reference on PubMed
    • View reference on publisher's website
  66. Futier E, Pereira B, Jaber S (2013) Intraoperative low-tidal-volume ventilation. N Eng J Med 369:1862–1863
    • View reference on publisher's website
  67. Lakhal K, Ehrmann S, Benzekri-Lefevre D, Runge I, Legras A, Dequin PF, Mercier E, Wolff M, Regnier B, Boulain T (2011) Respiratory pulse pressure variation fails to predict fluid responsiveness in acute respiratory distress syndrome. Crit Care 15:R85
    • View reference on PubMed
    • View reference on publisher's website
  68. Monnet X, Bleibtreu A, Ferre A, Dres M, Gharbi R, Richard C, Teboul JL (2012) Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med 40:152–157
    • View reference on PubMed
    • View reference on publisher's website
  69. Perel A, Minkovich L, Preisman S, Abiad M, Segal E, Coriat P (2005) Assessing fluid-responsiveness by a standardized ventilatory maneuver: the respiratory systolic variation test. Anesth Analg 100:942–945
    • View reference on PubMed
    • View reference on publisher's website
  70. Cannesson M, Le Manach Y, Hofer CK, Goarin JP, Lehot JJ, Vallet B, Tavernier B (2011) Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a “gray zone” approach. Anesthesiology 115:231–241
    • View reference on PubMed
    • View reference on publisher's website
  71. Michard F, Richards G, Biais M, Lopes M, Auler JO (2010) Using pulse pressure variation or stroke volume variation to diagnose right ventricular failure? Crit Care 14:451
    • View reference on PubMed
    • View reference on publisher's website

Sign In