Guidewire localization by transthoracic echocardiography during central venous catheter insertion: a periprocedural method to evaluate catheter placement

Jerome Bedel| Fabrice Vallée| Arnaud Mari| Beatrice Riu| Benjamin Planquette| Thomas Geeraerts| Michèle Génestal| Vincent Minville| Olivier Fourcade
Original Article
Volume 39, Issue 11 / November , 2013

Pages 1932 - 1937

Abstract

Purpose

To evaluate the feasibility of guidewire detection in right cardiac cavities by transthoracic echocardiography (TTE) in order to detect catheter misplacement and to optimize central venous catheter (CVC) positioning. Ultrasonic control for catheter tip positioning was compared to that by chest X-ray (CXR).

Methods

We conducted a monocentric prospective observational study (January–November 2010). All consecutive patients undergoing CVC insertion were included. The puncture was performed using the landmark method or ultrasound guidance. TTE was performed during the procedure to follow the arrival of the guidewire in the right cardiac cavities. Catheter misplacement was defined as an aberrant position on the postprocedural CXR (catheter positioning in ipsilateral or contralateral veins). The primary endpoint was the prediction of catheter misplacement by guidewire detection in the cardiac cavities. The secondary endpoint was the optimization of the catheter tip placement in the superior vena cava.

Results

A total of 98 patients received 101 CVC. The guidewire was visualized in 92 cases. In five cases, the guidewire was not seen in the right cardiac cavities and CXR showed catheter misplacement. In four cases, poor echogenicity led to the ultrasound examination being abandoned. Catheter misplacement was detected by TTE with a sensitivity of 96 % (CI 90–98 %), a specificity of 83 % (CI 44–97 %), a positive predictive value of 98 %, and a negative predictive value of 55 %. Likelihood ratios were LR+ 5.7 (CI 0.96–34.4) and LR− 0.05 (CI 0.02–0.14). Guidewire removal under TTE avoided an excessively distal position of the catheter tip in all cases.

Conclusion

TTE is a reliable tool to detect catheter misplacement and to optimize catheter tip positioning during the procedure of CVC insertion.

Keywords

References

  1. Sznader JI, Zveibil F, Bitterman H (1986) Central vein catheterization. Failure and complications rates by three percutaneous approaches. Arch Intern Med 146:259–261
    • View reference on publisher's website
  2. Mansfield PF, Hohn DC, Fornage BD, Gregurich MA, Ota DM (1994) Complications and failures of subclavian vein catheterization. N Engl J Med 331:1735–1738
    • View reference on PubMed
    • View reference on publisher's website
  3. Gladwin MT, Slonim A, Landucci DL (1999) Cannulation of the internal jugular vein: is a post procedural chest radiography always necessary? Critical Care Med 27:1819–1823
    • View reference on publisher's website
  4. Spiliotis J, Kordossis T, Kalfarentzos F (1992) The incidence of pneumothorax as a complication of subclavian vein catheterization. Br J Clin Pract 46:171–172
    • View reference on PubMed
  5. Lichtenstein D, Menu Y (1995) A bedside ultrasound sign ruling out pneumothorax in the critically ill: lung sliding. Chest 108:1345–1348
    • View reference on PubMed
    • View reference on publisher's website
  6. Lichtenstein D, Meziere G, Biderman P (1999) The comet-tail artefact: an ultrasound sign ruling out pneumothorax. Intensive Care Med 25:383–388
  7. Maury E, Guglielminotti J, Alzieu M (2001) Ultrasonic examination: an alternative to chst radiography after central venous catheter insertion. Am J Respir Crit Care Med 164:403–405
    • View reference on PubMed
    • View reference on publisher's website
  8. Vezzani A, Brusasco C, Palermo S, Corradi F (2010) Ultrasound localization of central venous catheter and detection of postprocedural pneumothorax: a alternative to chest radiography. Critical Care Med 38:533–538
    • View reference on publisher's website
  9. Gunst M, Ghaemmaghami V, Sperry J, Robinson M, O’Keefe T, Friese R, Frankel H (2008) Accuracy of cardiac function and volume status estimates using the besides echocardiographic assessment in trauma/critical care. J Trauma 65:509–516
    • View reference on PubMed
    • View reference on publisher's website
  10. Wirsing M, Shummer C, Rotraud N (2008) Is traditional reading of bedside chest radiography appropriate to detect intraatrial central venous catheter position? Chest 134:527–533
    • View reference on PubMed
    • View reference on publisher's website
  11. Aslamy Z, Dewald CL, Heffner JE (1998) MRI of central venous anatomy. Implications for central venous catheter insertion. Chest 114:820–826
    • View reference on PubMed
    • View reference on publisher's website
  12. Flahault A, Cadilhac M, Thomas G (2005) Sample size calculation should be performed for design accuracy in diagnostic test studies. J Clin Epidemiol 58:859–862
    • View reference on PubMed
    • View reference on publisher's website
  13. Lichtenstein D (1992) L’échographie générale en réanimation, 1st edn. Springer-Verlag, New York
  14. Roch A, Bojan M, Michelet P, Romain F, Papazian L, Auffray JP (2005) Usefulness of ultrasonography in predicting pleural effusions >500 mL in patients receiving mechanical ventilation. Chest 127:224–232
    • View reference on PubMed
    • View reference on publisher's website
  15. Lichtenstein D (2008) Relevance of lung ultrasound in the diagnosis of acute respiratory failure: the BLUE protocol. Chest 134:117–125
    • View reference on PubMed
    • View reference on publisher's website
  16. Randolph AG, Cook DJ, Gonzales CA, Pribble CG (1996) Ultrasound guidance for placement of central venous catheter: a meta-analysis of the literature. Critical Care Med 24:2053–2058
    • View reference on publisher's website
  17. Fletcher SJ, Bodenham AR (2000) Safe placement of central venous catheters: where should the tip of the catheter lie? Br J Anaesth 85:188–191
    • View reference on PubMed
    • View reference on publisher's website
  18. Walshe C, Phelan D, Bourke J, Buggy D (2007) Vascular erosion by central venous catheters used for total parenteral nutrition. Intensive Care Med 33:534–537

Sign In

Connect with ICM

Top 5 Articles Editors Picks Supplement