End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test

Xavier Monnet| Aurélien Bataille| Eric Magalhaes| Jérôme Barrois| Marine Le Corre| Clément Gosset| Laurent Guerin| Christian Richard| Jean-Louis Teboul
Original
Volume 39, Issue 1 / January , 2013

Pages 93 - 100

Abstract

Purpose

In stable ventilatory and metabolic conditions, changes in end-tidal carbon dioxide (EtCO2) might reflect changes in cardiac index (CI). We tested whether EtCO2 detects changes in CI induced by volume expansion and whether changes in EtCO2 during passive leg raising (PLR) predict fluid responsiveness. We compared EtCO2 and arterial pulse pressure for this purpose.

Methods

We included 65 patients [Simplified Acute Physiology Score (SAPS) II = 57 ± 19, 37 males, under mechanical ventilation without spontaneous breathing, 15 % with chronic obstructive pulmonary disease, baseline CI = 2.9 ± 1.1 L/min/m2] in whom a fluid challenge was decided due to circulatory failure and who were monitored by an expiratory-CO2 sensor and a PiCCO2 device. In all patients, we measured arterial pressure, EtCO2, and CI before and after a fluid challenge. In 40 patients, PLR was performed before fluid administration. The PLR-induced changes in arterial pressure, EtCO2, and CI were recorded.

Results

Considering the whole population, the fluid-induced changes in EtCO2 and CI were correlated (r2 = 0.45, p = 0.0001). Considering the 40 patients in whom PLR was performed, volume expansion increased CI ≥15 % in 21 “volume responders.” A PLR-induced increase in EtCO2 ≥5 % predicted a fluid-induced increase in CI ≥15 % with sensitivity of 71 % (95 % confidence interval: 48–89 %) and specificity of 100 (82–100) %. The prediction ability of the PLR-induced changes in CI was not different. The area under the receiver-operating characteristic (ROC) curve for the PLR-induced changes in pulse pressure was not significantly different from 0.5.

Conclusion

The changes in EtCO2 induced by a PLR test predicted fluid responsiveness with reliability, while the changes in arterial pulse pressure did not.

Keywords

References

  1. Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:2000–2008
    • View reference on PubMed
    • View reference on publisher's website
  2. Marik PE, Monnet X, Teboul JL (2011) Hemodynamic parameters to guide fluid therapy. Ann Intensive Care 1:1
    • View reference on PubMed
    • View reference on publisher's website
  3. Monnet X, Teboul JL (2008) Passive leg raising. Intensive Care Med 34:659–663
  4. Jabot J, Teboul JL, Richard C, Monnet X (2009) Passive leg raising for predicting fluid responsiveness: importance of the postural change. Intensive Care Med 35:85–90
  5. Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL (2006) Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 34:1402–1407
    • View reference on PubMed
    • View reference on publisher's website
  6. Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F (2008) Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth 101:761–768
    • View reference on PubMed
    • View reference on publisher's website
  7. Lafanechere A, Pene F, Goulenok C, Delahaye A, Mallet V, Choukroun G, Chiche JD, Mira JP, Cariou A (2006) Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients. Crit Care 10:R132
    • View reference on PubMed
    • View reference on publisher's website
  8. Lamia B, Ochagavia A, Monnet X, Chemla D, Richard C, Teboul JL (2007) Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity. Intensive Care Med 33:1125–1132
  9. Maizel J, Airapetian N, Lorne E, Tribouilloy C, Massy Z, Slama M (2007) Diagnosis of central hypovolemia by using passive leg raising. Intensive Care Med 33:1133–1138
  10. Monnet X, Osman D, Ridel C, Lamia B, Richard C, Teboul JL (2009) Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients. Crit Care Med 37:951–956
    • View reference on PubMed
    • View reference on publisher's website
  11. Preau S, Saulnier F, Dewavrin F, Durocher A, Chagnon JL (2010) Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis. Crit Care Med 38:989–990
    • View reference on publisher's website
  12. Monnet X, Bleibtreu A, Ferré A, Dres M, Gharbi R, Richard C, Teboul JL (2012) Passive leg raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med 40:152–157
    • View reference on PubMed
    • View reference on publisher's website
  13. Thiel SW, Kollef MH, Isakow W (2009) Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study. Crit Care 13:R111
    • View reference on PubMed
    • View reference on publisher's website
  14. Soubrier S, Saulnier F, Hubert H, Delour P, Lenci H, Onimus T, Nseir S, Durocher A (2007) Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients? Intensive Care Med 33:1117–1124
  15. Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M (2010) Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med 36:1475–1483
  16. Lamia B, Chemla D, Richard C, Teboul JL (2005) Clinical review: interpretation of arterial pressure wave in shock states. Crit Care 9:601–606
    • View reference on PubMed
    • View reference on publisher's website
  17. Monnet X, Letierce A, Hamzaoui O, Chemla D, Anguel N, Osman D, Richard C, Teboul JL (2011) Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine*. Crit Care Med 39:1394–1399
    • View reference on PubMed
    • View reference on publisher's website
  18. Tautz TJ, Urwyler A, Antognini JF, Riou B (2010) Case scenario: increased end-tidal carbon dioxide: a diagnostic dilemma. Anesthesiology 112:440–446
    • View reference on PubMed
    • View reference on publisher's website
  19. Weil MH, Bisera J, Trevino RP, Rackow EC (1985) Cardiac output and end-tidal carbon dioxide. Crit Care Med 13:907–909
    • View reference on PubMed
    • View reference on publisher's website
  20. Gudipati CV, Weil MH, Bisera J, Deshmukh HG, Rackow EC (1988) Expired carbon dioxide: a noninvasive monitor of cardiopulmonary resuscitation. Circulation 77:234–239
    • View reference on PubMed
    • View reference on publisher's website
  21. Vincent JL, Weil MH (2006) Fluid challenge revisited. Crit Care Med 34:1333–1337
    • View reference on PubMed
    • View reference on publisher's website
  22. Monnet X, Persichini R, Ktari M, Jozwiak M, Richard C, Teboul JL (2011) Precision of the transpulmonary thermodilution measurements. Crit Care 15:R204
    • View reference on PubMed
    • View reference on publisher's website
  23. Hanley JA, McNeil BJ (1983) A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 148:839–843
    • View reference on PubMed
  24. Anderson CT, Breen PH (2000) Carbon dioxide kinetics and capnography during critical care. Crit Care 4:207–215
    • View reference on PubMed
    • View reference on publisher's website
  25. Ornato JP, Garnett AR, Glauser FL (1990) Relationship between cardiac output and the end-tidal carbon dioxide tension. Ann Emerg Med 19:1104–1106
    • View reference on PubMed
    • View reference on publisher's website
  26. Garnett AR, Ornato JP, Gonzalez ER, Johnson EB (1987) End-tidal carbon dioxide monitoring during cardiopulmonary resuscitation. JAMA 257:512–515
    • View reference on PubMed
    • View reference on publisher's website
  27. Steedman DJ, Robertson CE (1990) Measurement of end-tidal carbon dioxide concentration during cardiopulmonary resuscitation. Arch Emerg Med 7:129–134
    • View reference on PubMed
  28. Falk JL, Rackow EC, Weil MH (1988) End-tidal carbon dioxide concentration during cardiopulmonary resuscitation. N Engl J Med 318:607–611
    • View reference on PubMed
    • View reference on publisher's website
  29. Cantineau JP, Lambert Y, Merckx P, Reynaud P, Porte F, Bertrand C, Duvaldestin P (1996) End-tidal carbon dioxide during cardiopulmonary resuscitation in humans presenting mostly with asystole: a predictor of outcome. Crit Care Med 24:791–796
    • View reference on PubMed
    • View reference on publisher's website
  30. Grmec S, Klemen P (2001) Does the end-tidal carbon dioxide (EtCO2) concentration have prognostic value during out-of-hospital cardiac arrest? Eur J Emerg Med 8:263–269
    • View reference on PubMed
    • View reference on publisher's website
  31. Levine RL, Wayne MA, Miller CC (1997) End-tidal carbon dioxide and outcome of out-of-hospital cardiac arrest. N Engl J Med 337:301–306
    • View reference on PubMed
    • View reference on publisher's website
  32. Baraka AS, Aouad MT, Jalbout MI, Kaddoum RN, Khatib MF, Haroun-Bizri ST (2004) End-tidal CO2 for prediction of cardiac output following weaning from cardiopulmonary bypass. J Extra Corpor Technol 36:255–257
    • View reference on PubMed
  33. Saleh HZ, Pullan DM (2011) Monitoring cardiac output trends with end-tidal carbon dioxide pressures in off-pump coronary bypass. Ann Thorac Surg 91:e81–e82
    • View reference on PubMed
    • View reference on publisher's website
  34. Rutlen DL, Wackers FJ, Zaret BL (1981) Radionuclide assessment of peripheral intravascular capacity: A technique to measure intravascular volume changes in the capacitance circulation in man. Circulation 64:146–152
    • View reference on PubMed
    • View reference on publisher's website
  35. Boulain T, Achard JM, Teboul JL, Richard C, Perrotin D, Ginies G (2002) Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients. Chest 121:1245–1252
    • View reference on PubMed
    • View reference on publisher's website
  36. Chemla D, Hebert JL, Coirault C, Zamani K, Suard I, Colin P, Lecarpentier Y (1998) Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans. Am J Physiol 274:H500–H505
    • View reference on PubMed
  37. Monge Garcia MI, Gil Cano A, Gracia Romero M, Monterroso Pintado R, Perez Madueno V, Diaz Monrove JC (2012) Non-invasive assessment of fluid responsiveness by changes in partial end-tidal CO2 pressure during a passive leg-raising maneuver. Ann Intensive Care 2:9
    • View reference on PubMed
    • View reference on publisher's website
  38. Vincent JL, Rhodes A, Perel A, Martin GS, Rocca GD, Vallet B, Pinsky MR, Hofer CK, Teboul JL, de Boode WP, Scolletta S, Vieillard-Baron A, De Backer D, Walley KR, Maggiorini M, Singer M (2011) Clinical review: update on hemodynamic monitoring - a consensus of 16. Crit Care 15:229
    • View reference on PubMed
    • View reference on publisher's website
  39. Antonelli M, Levy M, Andrews PJ, Chastre J, Hudson LD, Manthous C, Meduri GU, Moreno RP, Putensen C, Stewart T, Torres A (2007) Hemodynamic monitoring in shock and implications for management. International Consensus Conference, Paris, France, 27–28 April 2006. Intensive Care Med 33:575–590
  40. De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL (2005) Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 31:517–523
  41. Vallee F, Richard JC, Mari A, Gallas T, Arsac E, Verlaan PS, Chousterman B, Samii K, Genestal M, Fourcade O (2009) Pulse pressure variations adjusted by alveolar driving pressure to assess fluid responsiveness. Intensive Care Med 35:1004–1010
  42. Malbrain ML, Reuter DA (2010) Assessing fluid responsiveness with the passive leg raising maneuver in patients with increased intra-abdominal pressure: be aware that not all blood returns! Crit Care Med 38:1912–1915
    • View reference on PubMed
    • View reference on publisher's website