Impact of volume guarantee on synchronized ventilation in preterm infants: a randomized controlled trial

Nuray Duman| Funda Tuzun| Sumer Sutcuoglu| Cemile Didem Yesilirmak| Abdullah Kumral| Hasan Ozkan
Pediatric Original
Volume 38, Issue 8 / August , 2012

Pages 1358 - 1364

Abstract

Purpose

The aim of this randomized controlled trial was to assess whether the addition of volume guarantee (VG) to triggered ventilation decreases the duration of ventilation in very low birth weight (VLBW) infants with respiratory distress syndrome (RDS).

Methods

Infants were randomized into two groups to initially receive either assist/control (A/C) or A/C plus VG ventilation and then weaned with synchronized intermittent mandatory ventilation (SIMV) or SIMV plus VG.

Results

Forty-five infants were included in the study. The demographic and clinical characteristics, values of tidal volume (VT), peak inspiratory pressure (PIP), fraction of inspired oxygen, carbon dioxide tension, and pH were similar for all participating infants initially. During the follow-up, the VT levels were more stable, and the PIP levels were significantly decreasing in the VG group. Although the duration of ventilation was shorter in the VG group, this trend was not statistically significant. The incidences of death and bronchopulmonary dysplasia (BPD) were not significantly different, but the combined outcome of death or BPD was lower in the VG group. Although the VG group experienced less frequent BPD, periventricular leukomalacia, and intraventricular hemorrhage, these differences were not statistically different.

Conclusion

The VG option, when combined with A/C (in the acute phase of RDS) and SIMV (in the weaning), reduced VT variability, and may have shortened the duration of ventilation in VLBW infants. Overall mortality and BPD rates did not change, but their combined outcome was significantly improved in infants treated with VG modes as compared to those treated with synchronized pressure-limited modes alone.

Keywords

References

  1. Keszler M (2006) Volume guarantee and ventilator-induced lung injury: Goldilock’s rules apply. Pediatr Pulmonol 41:364–366
    • View reference on PubMed
    • View reference on publisher's website
  2. Wheeler K, Klingenberg C, McCallion N, Morley CJ, Davis PG (2010) Volume-targeted versus pressure-limited ventilation in the neonate. Cochrane Database Syst Rev 10:CD003666
  3. Gibbs RS, Duff P (1991) Progress in pathogenesis and management of clinical intraamniotic infection. Am J Obstet Gynecol 164:1317–1326
    • View reference on PubMed
  4. Ozkan H, Duman N, Kumral A, Gulcan H (2004) Synchronized ventilation of very-low-birth-weight infants; report of 6 years’ experience. J Matern Fetal Neonatal Med 15:261–265
    • View reference on PubMed
    • View reference on publisher's website
  5. Abubakar K, Keszler M (2005) Effect of volume guarantee combined with assist/control vs synchronized intermittent mandatory ventilation. J Perinatol 25:638–642
    • View reference on PubMed
    • View reference on publisher's website
  6. Cheema IU, Ahluwalia JS (2001) Feasibility of tidal volume-guided ventilation in newborn infants: a randomized, crossover trial using the volume guarantee modality. Pediatrics 107:1323–1328
    • View reference on PubMed
    • View reference on publisher's website
  7. Abubakar KM, Keszler M (2001) Patient-ventilator interactions in new modes of patient-triggered ventilation. Pediatr Pulmonol 32:71–75
    • View reference on PubMed
    • View reference on publisher's website
  8. Keszler M, Abubakar K (2004) Volume guarantee: stability of tidal volume and incidence of hypocarbia. Pediatr Pulmonol 38:240–245
    • View reference on PubMed
    • View reference on publisher's website
  9. Dawson C, Davies MW (2005) Volume-targeted ventilation and arterial carbon dioxide in neonates. J Paediatr Child Health 41:518–521
    • View reference on PubMed
    • View reference on publisher's website
  10. Keszler M, Nassabeh-Montazami S, Abubakar K (2009) Evolution of tidal volume requirement during the first 3 weeks of life in infants <800 g ventilated with volume guarantee. Arch Dis Child Fetal Neonatal Ed 94:F279–F282
    • View reference on PubMed
    • View reference on publisher's website
  11. Nafday SM, Green RS, Lin J, Brion LP, Ochshorn I, Holzman IR (2005) Is there an advantage of using pressure support ventilation with volume guarantee in the initial management of premature infants with respiratory distress syndrome? A pilot study. J Perinatol 25:193–197
    • View reference on PubMed
    • View reference on publisher's website
  12. Lista G, Colnaghi M, Castoldi F, Condo V, Reali R, Compagnoni G, Mosca F (2004) Impact of targeted-volume ventilation on lung inflammatory response in preterm infants with respiratory distress syndrome (RDS). Pediatr Pulmonol 37:510–514
    • View reference on PubMed
    • View reference on publisher's website
  13. Cheema IU, Sinha AK, Kempley ST, Ahluwalia JS (2007) Impact of volume guarantee ventilation on arterial carbon dioxide tension in newborn infants: a randomised controlled trial. Early Hum Dev 83:183–189
    • View reference on PubMed
    • View reference on publisher's website
  14. Singh J, Sinha SK, Alsop E, Gupta S, Mishra A, Donn SM (2009) Long term follow-up of very low birthweight infants from a neonatal volume versus pressure mechanical ventilation trial. Arch Dis Child Fetal Neonatal Ed 94:F360–F362
    • View reference on PubMed
    • View reference on publisher's website
  15. Singh J, Sinha SK, Clarke P, Byrne S, Donn SM (2006) Mechanical ventilation of very low birth weight infants: is volume or pressure a better target variable? J Pediatr 149:308–313
    • View reference on PubMed
    • View reference on publisher's website
  16. D’Angio CT, Chess PR, Kovacs SJ, Sinkin RA, Phelps DL, Kendig JW, Myers GJ, Reubens L, Ryan RM (2005) Pressure-regulated volume control ventilation vs synchronized intermittent mandatory ventilation for very low-birth-weight infants: a randomized controlled trial. Arch Pediatr Adolesc Med 159:868–875
    • View reference on PubMed
    • View reference on publisher's website
  17. Sinha SK, Donn SM, Gavey J, McCarty M (1997) Randomised trial of volume controlled versus time cycled, pressure limited ventilation in preterm infants with respiratory distress syndrome. Arch Dis Child Fetal Neonatal Ed 77:F202–F205
    • View reference on PubMed
    • View reference on publisher's website
  18. Antonelli M, Azoulay E, Bonten M, Chastre J, Citerio G, Conti G, De Backer D, Gerlach H, Hedenstierna G, Joannidis M, Macrae D, Mancebo J, Maggiore SM, Mebazaa A, Preiser JC, Pugin J, Wernerman J, Zhang H (2010) Year in review in Intensive Care Medicine 2010: III. ARDS and ALI, mechanical ventilation, noninvasive ventilation, weaning, endotracheal intubation, lung ultrasound and paediatrics. Intensive Care Med 37:394–410

Sign In

Connect with ICM

Top 5 Articles Editors Picks Supplement